Future Star Laboratories
Subject 06 · Experimentation
  1. Pump-down time
  2. Pumps

Vacuum Systems

How a chamber is pumped down: first the gas in the volume, then the gas stuck to its surfaces, then the limits of the pumps themselves.

Notebook · 06 of 08
t = 2.3 (V / S) log(P₁ / P₂)
V in litres, S in litres per second
§1 · Vacuum Systems

Pump-down time

The time to go from P₁ to P₂ comes from the chamber volume and the average pumping speed. It holds while the speed stays close to its average and the target pressure is at least ten times the base pressure.

Pumping speeds are usually quoted for nitrogen. Other gases need a correction for molecular weight.

t = 2.3 (V / S) log(P₁ / P₂)V in litres, S in litres per second
§2 · Vacuum Systems

Pumps

  • Oil diffusion: hot oil vapour knocks gas molecules toward the exhaust
  • Molecular drag: a spinning rotor sweeps molecules through grooves and compresses them toward the exhaust
  • Gas ballast: handles vapours that condense, such as water